Jacobs Wind Energy Systems
Em"Powering" Consumers Since 1986
username:
password:
Home or Create Account
Site - Washoe Valley, NV: Current Conditions Production Data System Health Settings

Now:

Turbine / Inverter Information Weather Sensors
Status: RUN Sensor: Current Maximum
Power: 0 watts (0.0 kW) out Anemometer 0: 8.8 MPH / 3.9 m/s 10.5 MPH / 4.7 m/s
Misc Stats: Blade Speed: 72 RPM Wind Vane: 10° (add cardinal direction)
Generator Speed: 439 RPM Temperature: -457.7°F / -272.1°C
Technical / Engineering Data
Utility Voltage: 244.3 VAC Utility Frequency: 60.0 Hz
Utility Current: 0.0 amps Power Factor: 1.00
Generator Voltage: 78.8 volts Inverter Temperature: 35°C / 95°F
Rectifier Voltage: 106.7 volts Rectifier Temperature: 36°C / 97°F
Boost Voltage: 398.9 volts Boost Current: 6553.5 amps
Field Current: 0.5 amps Output VA: 0 VA
DSP Version: 1.00 Horner Version: 1.10
Last Fault(s): Low temperature fault over 65 seconds ago.


Wind Turbine Industries, Corp. - 16801 Industrial Circle S.E. - Prior Lake, MN 55372
Phone: 1-952-447-6064 - Fax: 1-952-447-6050
© 2017. All rights reserved.

Powered by an APRS World solution.