Jacobs Wind Energy Systems
Em"Powering" Consumers Since 1986
username:
password:
Home or Create Account
Site - Washoe Valley, NV: Current Conditions Production Data System Health Settings

Now:

Turbine / Inverter Information Weather Sensors
Status: RUN Sensor: Current Maximum
Power: 11,400 watts (11.4 kW) out Anemometer 0: 23.7 MPH / 10.6 m/s 24.4 MPH / 10.9 m/s
Misc Stats: Blade Speed: 160 RPM Wind Vane: 133° (add cardinal direction)
Generator Speed: 976 RPM Temperature: -450.2°F / -267.9°C
Technical / Engineering Data
Utility Voltage: 244.4 VAC Utility Frequency: 60.0 Hz
Utility Current: 47.1 amps Power Factor: 0.99
Generator Voltage: 189.9 volts Inverter Temperature: 48°C / 120°F
Rectifier Voltage: 254.6 volts Rectifier Temperature: 48°C / 119°F
Boost Voltage: 452.2 volts Boost Current: 46.6 amps
Field Current: 0.8 amps Output VA: 11,500 VA
DSP Version: 1.00 Horner Version: 1.10


Wind Turbine Industries, Corp. - 16801 Industrial Circle S.E. - Prior Lake, MN 55372
Phone: 1-952-447-6064 - Fax: 1-952-447-6050
© 2017. All rights reserved.

Powered by an APRS World solution.